Page:Guillaume Paumier - Technologies PNIPAM pour les laboratoires sur puces.djvu/117

Cette page n’a pas encore été corrigée
  • [114] H. Yim, M.S. Kent, S. Mendez, S.S. Balamurugan, S. Balamurugan, G.P. Lopez et S. Satija : Temperature-dependent conformational change of grafted chains at high surface density in water. Macromol., 37(5):1994–1997, 2004, doi:10.1021/ma0354290.
  • [115] H.G. Schild : Poly(N-isopropylacrylamide): Experiment, theory and application. Prog. Polym. Sci., 17(2):163–249, 1992, doi:10.1016/0079-6700(92)90023-R.
  • [116] R. Pelton : Temperature-sensitive aqueous microgels. Adv. Colloid. Interface Sci., 85(1):1–33, Feb. 2000, doi:10.1016/S0001-8686(99)00023-8. [Revue].
  • [117] Y.V. Pan, R.A. Wesley, R. Luginbuhl, D.D. Denton et B.D. Ratner : Plasma polymerized N-isopropylacrylamide: Synthesis and characterization of a smart thermally responsive coating. Biomacromol., 2(1):32–36, 2001, doi:10.1021/bm0000642.
  • [118] P.S. Curti, M.R. De Moura, E. Radovanovic, A.F. Rubira, E.C. Muniz et R.A. Moliterno : Surface modification of polystyrene and poly(ethylene terephtalate) by grafting poly(N-isopropylacrylamide). J. Mater. Sci. Mater. Med., 13(12):1175–1180, Dec 2002, doi:10.1023/A:1021154424189.
  • [119] P. Heinz, F. Bretagnol, I. Mannelli, L. Sirghi, A. Valsesia, G. Ceccone, D. Gilliland, K. Landfester, H. Rauscher et F. Rossi : Poly(N-isopropylacrylamide) grafted on plasma-activated poly(ethylene oxide): Thermal response and interaction with proteins. Langmuir, 24(12):6166––6175, May 2008, doi:10.1021/la800575f.
  • [120] G. Graziano : On the temperature-induced coil to globule transition of poly-N-isopropylacrylamide in dilute aqueous solutions. Int. J. Biol. Macromol., 27(1):89–97, Mar. 2000, doi:10.1016/S0141-8130(99)00122-1.
  • [121] A. Estève, A. Bail, G. Landa, A. Dkhissi, M. Brut, M. Djafari Rouhani, J. Sudor et A.-M. Gué : A new insight into the understanding of the collapsed form of poly(N-isopropylacrylamide) molecules. Chem. Phys., Volume 340(1-3):12–16, Nov. 2007, doi:10.1016/j.chemphys.2007.06.054.
  • [122] G. Zhang : Study on conformation change of thermally sensitive linear grafted poly(N-isopropylacrylamide) chains by quartz crystal microbalance. Macromol., 37(17):6553–6557, 2004, doi:10.1021/ma035937+.
  • [123] G. Liu et G. Zhang : Collapse and swelling of thermally sensitive poly(N-isopropylacrylamide) brushes monitored with a quartz crystal microbalance. J. Phys. Chem. B, 109(2):743–747, 2005, doi:10.1021/jp046903m.
  • [124] N. Ishida et S. Biggs : Direct observation of the phase transition for a poly(n-isopropylacryamide) layer grafted onto a solid surface by and QCM-D. Langmuir, 23(22):11083–11088, Oct. 2007, doi:10.1021/la701461b.
  • [125] M. Annaka, C. Yahiro, K. Nagase, A. Kikuchi et T. Okano : Real-time observation of coil-to-globule transition in thermosensitive poly(n-isopropylacrylamide) brushes by quartz crystal microbalance. Polymer, 48(19):5713–5720, Sept. 2007, doi:10.1016/j.polymer.2007.06.067.
  • [126] C. Ramkissoon-Ganorkar, A. Gutowska, F. Liu, M. Baudys et S. W. Kim : Polymer molecular weight alters properties of pH-/temperature-sensitive polymeric beads. Pharm Res, 16(6):819–827, Jun 1999, doi:10.1023/A:1018813700535.